Signalling Cable Type E1, E2, E3

- Eland Product Group:
- A5R
- Application:
- LSZH signalling cable suitable for tails
- Standards:
- NR/PS/SIG/00005 (formerly RT/E/PS/00005
- Conductor:
- Class 5 tinned conductor to BS6360
- Insulation:
- LSZH or EPR type GP4
- Drain wire:
- Type E3 only
- Sheath:
- LSZH
- Colour:
- Black
- Voltage Rating:
- 650/1100V
- Temperature Rating:
- -25 to +85°C
Specifications Data
Download detailed Signalling Cable Type E1, E2, E3 specifications as a PDF file (152kb)
| Rail Catalogue Number | No. of Cores x Nominal Cross Sectional Area# x mm² | No. and Nominal Diameter of Strands#/mm | Overall Diameter Min.mm | Overall Diameter Max.mm | Nominal Weightkg/Km |
|---|---|---|---|---|---|
| 6/120172 | 1 x 2.5 | 50/0.25 | 11.2 | 14.0 | 174 |
| 6/120170 | 2 x 2.5 | 50/0.25 | 14.9 | 18.8 | 359 |
| 6/120171 | 4 x 2.5 | 50/0.25 | 16.4 | 20.9 | 445 |
| 6/120173 | 7 x 2.5 | 50/0.25 | 18.7 | 23.7 | 590 |
| 6/120174 | 10 x 2.5 | 50/0.25 | 22.5 | 28.6 | 784 |
| 6/120175 | 12 x 2.5 | 50/0.25 | 23.2 | 29.3 | 868 |
| 6/120176 | 16 x 2.5 | 50/0.25 | 25.3 | 32.0 | 980 |
| 6/160090 | 1 x 2 x 2.5 | 50/0.25 | 15.0 | 20.0 | 341 |